Sayantan Basu
  • Member for 6 years, 10 months
  • Last seen more than a week ago
  • Mumbai
Publication Id for the DXA Page is unknown
Accepted answer
6 votes

You don't need any separate configuration for that. In DXA there is a container called Localization to store the requested Publication information. You can retrieve the publication id from that ...

View answer
Upgrade SDL web 8 from Tridion 2013 SP1
6 votes

All the step are well defined in the SDL Web 8 document under Upgrading SDL Web section. This section describes how you can upgrade from an earlier version to SDL Web 8.

View answer
Is it possible to set/change the Expiration Time of Workflow Activity Dynamically?
Accepted answer
6 votes

I have implemented the code using Tridion.ContentManager.CoreService.Workflow and there are 2 properties called - public DateTime? DueDate { get; set; } Under ActivityData class public DateTime? ...

View answer
SI4T Elastic Search -- Data not being indexed
Accepted answer
4 votes

In Sites 9 Regions are newly introduced to structure the content on a page in a better way. So the page is having a new structure now. The idea is while publishing the page we need to handle this ...

View answer
Topology Manager | How to create multiple Topology Environments
Accepted answer
4 votes

For creating multiple environment first you have to create multiple instances of discovery service. What I understand from the error message is DiscoveryEndpointUrl is already in used by one ...

View answer
Switching on HTTP Activation in IIS
Accepted answer
4 votes

Yes! That is sufficient to enable HTTP activation from IIS.

View answer
RetroFit Mode with DXA for Schemas using Content as Root node
Accepted answer
3 votes

We have used Retrofit mode for one of our client.I have documented the steps to install/enable the retrofit which you can try this. I personnaly prefer to enable the retrofit mode instead of changing ...

View answer
How to add XPM tags for component linked field and embedded fields in DXA 1.2
3 votes

You need to add the DXAPropertyMarkup in the right place. As you are using multiple linked component field, so I will suggest you to add markup in the div immediately after the for loop - it will be ...

View answer
DXA model mapping issue
Accepted answer
3 votes

Yes! It is possible but need some customization on the DD4T template. DD4T template does not add the schema information (for folder and structure group metadata) in the presentation and because of ...

View answer
Tridion 2013 SP1 publishing fails with following error "Transport service failed to transport"
3 votes

As per the error message Unable to establish transport to destination. That means your connection between CMS server and Destination server is disconnected that's why it stopped working suddenly. ...

View answer
content not changing in dd4t
3 votes

We have faced the same type of issue previously and it was because of the built in caching property of DD4T. As Rob already suggested the solution. I am just adding an additional way to handle this ...

View answer
How do I configure my web application for Binding with core service?
3 votes

You can use the code below to create a core service client in your web application: /// <summary> /// Core service client configuration /// </summary> /// <returns>return the ...

View answer
Fredhopper Installation on Linux server
Accepted answer
3 votes

you will find all the details of fredhopper installation in the below link - https://www.fredhopper.com/learningcenter [password required]

View answer
Tridion sites 9.1 - the Business Process Type (in publishing tab) is from time to time switched to 'None'
2 votes

I faced the similar issue recently and that was because of the content import (using content importer or using import export service). You can check if there is a content porting activity that happens ...

View answer
How to insert HTML content on Source tab of Rich Text Field using Tridion Core Service?
2 votes

When dealing with Rich Text fields the best approach is to convert HTML to XHTML using Tidy.NET. That also ensures your content is valid Xhtml. Nuno already described the process in this blog. Check ...

View answer
Unable to update existing embedded schema Root element name
Accepted answer
2 votes

Definitely, there is a way to achieve this, but before you do that change you need to be very careful about your data. I will suggest while doing that change in the lower environment analyze it ...

View answer
DXA RetroFit - Model Annotations for Embedded Schemas?
Accepted answer
2 votes

Yes indeed, you have to use the same prefix from the Parent and Embedded Schemas otherwise mapping will not work properly. Also use this for all the schemas and embedded schemas. So your Embedded ...

View answer
DXA 1.6 cms upgrade script
2 votes

Yes! the DXA Framework is separated from basic but optional Views and View Models that were used in example implementation from DXA 1.6 onward. If you are installing it in CMS for your existing ...

View answer
ECL Adapter and SDL Web 8 - How is ECL Dll linked to SDL Web 8
2 votes

This entry should be in the Tridion.ContentManager.config file Under {Tridion Home}\config\ folder. Search for extensions tag. Under that tag you can find the entry for ECL Library. If it is not ...

View answer
How to resolve ECL components in rich text fields
Accepted answer
2 votes

I am assuming that you are using DXA Media Manager module and you have already created a Model for the Media Manager item, if not then add a Model in your project. Here is the sample for that; [...

View answer
Issue with meta query on web 8.5
2 votes

I have faced same type issue with multiple CustomMetaValueCriteria. So to overcome that, I have changed my query like below. For me it is working fine now. Could you try the below code once - This ...

View answer
Getting list of published pages againtst a specific target type in specific business process type
2 votes

In web 8 there is a new concept introduced as “Purpose” to manage all the publishing target settings directly into the Topology Manager. So In web 8, instead of defining the Target Type / Publishing ...

View answer
Setting up Content Delivery for the sample single-machine installation for SDL Web 8
2 votes

What I can see it is a typo in the powershell. You have missed to put the -license attribute before the FILE. Here is the command for your reference - & '.\quickinstall.ps1 -license FILE -...

View answer
Get a list of valid users and groups for for a specific component or page
2 votes

I have implemented the same type of feature in my project. Here are the steps that I have followed - First read the all the tasks from that workflow process. Then read the group involved in that ...

View answer
Facing issue while editing the workflow diagram?
2 votes

Previously I have also faced the same type of issue in our project. Below is the workaround for that uninstall the Visio 2010 SP2 install Microsoft Visio 2010 SP1 (x86). Then try it again.

View answer
Core service unable to retrive the component from newlly created folder based on schema
Accepted answer
2 votes

The issue is resolved now. The Search indexer service went down initially because of which the data was not indexed properly. As a resolution, I have restarted the indexer and search host services ...

View answer
DXA development documents
2 votes

For development you can refer the official documentation link

View answer
How Translation Manager Events Work Internally?
Accepted answer
2 votes

Logically your code is fine. But Instead of EventArgs I suggest you to use TranslationJobStateChangeEventArgs. Hopefully It will resolve your problem.. Here is the code for reference - public ...

View answer
Error setting up the SDL Web Discovery Service
2 votes

I have faced the same problem at the time of installation. Later I found the issue is related to the SQL Server Port. Go to the SQL Configuration Manager and check the TCP/IP port is assigned to 1433 ...

View answer
is there way to rollback published content when workflow step reassigned to Editor?
2 votes

As Alvin suggested, I also think automatic activity is the best way to fulfill your requirement - When your approver reject the item instead of reassign it to editor, assign it to a automatic ...

View answer